Part Number Hot Search : 
LPS44 IRFD11 1N4739AG SSF5N60F 31040 SD758 SOT23 2SD1320P
Product Description
Full Text Search
 

To Download M02-04-01 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  gamewell-fci 12 clintonville road, northford, ct 06472-1610 usa ? tel: (203) 484-7161 ? fax: (203) 484-7118 specifications are for information only, are not intended for in stallation purposes, and are subj ect to change wi thout notice. no responsibility is assumed by gamewell-fci for their use. ?2013 by honeywell international inc. all rights reserved. www.gamewell-fci.com 9021-60708 rev. c page 1 of 2 velociti ? series mcs-cof advanced multi-criteria fire/co detector signaling s1195 7275-1703:0175 description the advanced multi-criteria fire/co detector (mcs- cof) is an addressable devi ce that provides both fire and carbon monoxide (co) detection. for fire detec- tion, the detector combines the following four sepa- rate sensing elements in one unit. ? smoke ? carbon monoxide (co) ? light/flame ? heat these elements sense multiple components of a fire. this approach enables an enhanced sensitivity to real fire with a heightened immunity to nuisance par- ticulate. for co, the detect or?s electrochemical sens- ing cell creates a separate signal for life safety co detection. released through the incomplete burning of various fuels, co is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. because the potential exists for dangerous levels of co to accumula te in almost any building, legislation mandates the use of co detection in com- mercial spaces in the u.s. the mcs-cof is listed to the ul ? 2075 standard for system-connected life safety carbon mono xide monitoring. it is designed to be used with the gamewell-fci, e3 series or s3 series fire alarm control panel only. the mcs-cof should be used in conjunction with the b200s intelligent sounder base, which can generate either of the following patterns: ? temp 3 pattern for fire. ? temp 4 pattern for co alarm indication. ? the b200s recognizes the system sensor synchro- nization protocol. this feature enables it to be used as a component of the general evacuation signal, along with other system sens or horns, horn strobes, and chimes, when the mcs-cof is connected to a power supply or fire alarm control panel (facp) output that is capable of generating the system sen- sor synchronization pulses. with each sounder base carrying a unique address, the facp can then com- mand an individual sounder, or a group of sounders, to activate. the command set from the panel can be tailored to the specific ev ent, allowing selection of volume, tone, and group. for more information on the b200s, refer to data sheet p/n: 9021-60671. ? e3 series ? is a registered trademark of honeywell international inc. ul ? is a registered trademark of underwriters laboratories inc. ? features ? offers the unique function to detect the following four major elements of a fire: - smoke - carbon monoxide (co) - light/flame - heat ? supplies a separate co detection signal. ? presents the highest nuisance alarm immunity. ? produces an automatic drift compensation of smoke sensor and co cell. ? uses only one address on the slc. ? includes the easytest co testing capability. ? complies with ul ? listed standard 268 and ul ? listed standard 2075. ? separates the audible signal for fire or co alarm when used with the b200s base. ? provides the co cell end-of-life warning and fault. mcs-cof in a b200s sounder base
gamewell-fci 12 clintonville road, northford, ct 06472-1653 usa ? tel: (203) 484-7161 ? fax: (203) 484-7118 9021-60708 rev. c page 2 of 2 www.gamewell-fci.com ? ? specifications physical specifications base diameter: 6.875? (17.46 cm) installed in a b200s base base height: 3.46? (8.79 cm) installed in b200s base shipping weight: 4.6 oz color: ivory material: bayblend fr110 operating temperature range: 32 f to 100 f (0 c to 38 c) operating humidity range: 15 to 90% relative humidity (non-condensing) air velocity: 0 to 4,000 ft/min (0 to 20 m/sec) electrical specifications operating voltage range: 15 to 32 vdc maximum standby current: 300 a at 24 vdc (no communica- tion every 5 seconds with led blink enabled). maximum alarm current (led on): 7.2 ma at 24 vdc sensitivity settings & suggested applications level 1: 1% per foot (30.48 cm) of smoke. very clean environments: used in laboratories. level 2: 2% per foot (30.48 cm) of smoke. clean environments: used in offices. level 3: 3% per foot (30.48 cm) of smoke. moderately clean environments: used in hotel rooms, dorm rooms. level 4: 3% per foot (30.48 cm) of smoke with different algorithm processing an d weighting of sensor elements. used in hotel rooms near a shower, boiler rooms. level 5: 4% per foot (30.48 cm) of smoke. used in equipment rooms, kitchens, paint shop. level 6: thermal alarm at 135 f (57 c). warning: after the co cell has reac hed the end-of-life, the co sensor no longer provides life safety protection. how- ever, when the fire detector enters photo, thermal, infra- red (ptir) mode, the follo wing sensitivities apply: level 1: 1% per foot (30.48 cm) of smoke. very clean environments: used in laboratories. level 2: 2% per foot (30.48 cm) of smoke. clean environments: used in offices. level 5: 3% per foot (30.48 cm) of smoke. moderately clean environments: used in hotel rooms, dorm rooms. level 6: thermal alarm at 135 f (57 c). specifications (continued) co monitoring ul stan dard reference - alarm thresholds are as follows: parts per million 70 5ppm 1505ppm 400 10ppm detector response time, min. 60-240 10-50 4-15 note: per ul standard 2075, the mcs-cof has been tested to the sensitivity limi ts defined in ul standard 2034. ordering information part number description mcs-cof advanced multi-criteria fire/co detector note: due to the unique nature of this detector, please consult your fire alarm control panel manufacturer for the specific model and compatibility. accessories: b200s addressable sounder base M02-04-01 detector test magnet m02-09-01 telescoping test magnet


▲Up To Search▲   

 
Price & Availability of M02-04-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X